Home FEEDBACK SITE MAP SERVICES NEWS BACKGROUND CONTACT INFO

NEWS
  

Fire Extinguishers
USCG AFFF Foam
Fixed Fire Systems
Fire Detection
Fireman's Gear
Breathing Apparatus
Fire Hoses
Nozzles & Adapters
Cabinets/Brackets
Yacht Cabinets
Safety Equipment
Towboat Packages
Marina Packages
Bio Terror/Tactical
Medical Supplies
Specials / Sales

 


IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE

Brookdale Product Recall / Refund Announcement:

Return Period Ended
 

Following our "Suspend Use" advisory of March 8, 2006, and in cooperation with the U.S. Consumer Product Safety Commission (CPSC), Brookdale International Systems Inc. voluntarily recalled all EVAC-U8 and EVAC+ emergency escape smoke hoods currently in the marketplace worldwide that had not reached their expiration date. These products were purchased to provide respiratory protection in a structural smoke/fire emergency.

Recent tests have confirmed that use of these products in a smoke or fire emergency may expose the user to harmful carbon monoxide, which could seriously compromise their ability to escape a fire threat. Therefore, these products SHOULD NOT BE USED. The company is not aware of any incidents where a user of these products was exposed to harmful levels of carbon monoxide.

Customers who returned Brookdale smoke hoods before the stated return period deadline have already or will shortly receive a prorated refund based on the remaining shelf life, as indicated by the expiration date printed (along with the serial number) on the side of each canister. Units that reached their expiry date prior to March 2006 were not eligible for refund. As set out in the user's manual, all expired units should be discarded.

The deadline for returning products for refund from customers outside Europe was June 16, 2006. For logistical reasons the European deadline was June 30th.

A recall was also in effect for the following SCBA emergency escape respirators. The return deadline for these products has also passed.

 

  • EVACpro for Scott Emergency Escape Respirator
  • EVACpro for Dräger Emergency Escape Respirator
  • Survivair SmokeEater Air-Purifying Escape Canister
Brookdale sincerely regrets any inconvenience created by this product recall. We have been, and continue to be working diligently to rectify this situation in a safe, thorough and responsible manner. Our highest priority is the safety of our customers, and the steps we have taken are a demonstration of that commitment.

Brookdale does not anticipate having replacement products available in the near future.

Yours truly,

Derrick Russell
President, Brookdale International Systems Inc.
 

PLEASE VISIT www.evacsafety.com FOR FURTHER INFORMATION

___________________________________________________________________________________

TOWBOAT ALERT

[Code of Federal Regulations]
[Title 46, Volume 1]
[Revised as of October 1, 2004]
From the U.S. Government Printing Office via GPO Access
[CITE: 46CFR27.303]

[Page 320]
 
                           TITLE 46--SHIPPING
 
         CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
 
PART 27_TOWING VESSELS--Table of Contents
 
         Subpart C_Fire-Suppression Equipment for Towing Vessels
 
Sec. 27.303  What are the requirements for fire-extinguishing equipment

on towing vessels in inland service, and on towing vessels in ocean or
coastal service
          whose construction was contracted for before August 27, 2003?

    You must carry on your towing vessel both--
    (a) The minimum number of hand-portable fire extinguishers required
by subpart 25.30 of this part; and
    (b) By April 29, 2005, either--
    (1) An approved B-V semi-portable fire-extinguishing system to
protect the engine room; or
    (2) A fixed fire-extinguishing system installed to protect the
engine room of the vessel.

CLICK HERE FOR FURTHER INFORMATION ON THIS REGULATION

________________________________________________________________________________________________________________________________

 

FIREMAN'S OUTFIT AND BREATHING APPARATUS
 

These are the press releases we've issued over the last year. You may want to search for topics by keyword.

  • Date -- January 10th, 2005
    Western Fire & Safety gets ABS Americas Division Approval for 46CFR Compliant Fireman's Outfits and Self-Contained Breathing Apparatus.
  • ABS has completed the design assessment, and approved our model number WFSFRMN/101/TYP/ABS on January 10th, 2005, with Certificate Number 05-HS473282-PDA. For details, please access ABS website at www.eagle.org/contents.html and click on Product Search, and enter Fireman's Suit in the keyword to receive the following information:
  • Western Fire & Safety Co., Inc.
    2446 NW Market Street
    Seattle
    Washington 98107
    United States of America
    Tel 206-782-7825
    Fax 206-783-5748
     
    FIREMANS SUIT AND SCBA

       

           
    E-mail sales@westernfireandsafety.com
    Website westernfireandsafety.com

    Product Fireman's Outfit & Self Contained Breathing Apparatus
     
    Model WFSFRMN/101/TYP/ABS
     
    Intended Service Fire Fighting on-board Commercial US Flag Vessels
     
    Description Fireman's Outfit ("A" items) and Self Contained Breathing Apparatus ("B" items) consisting of the following principal components - A.1. Coat, 35 inch (FRMN/400); Pants, waist-level (FRMN/450); Suspenders, elastic (FRMN/500). Coat, pants and suspenders are components of Quaker Safety Products Corporation MD-35 Style Structural Fire Fighting Protective Clothing. A.2. Fireman's Helmet, with Visor, Chieftain 911 model (FRMN/300/911) A.3. Fireman's Gloves, Firedex (FRMN/250/GOI BLMWN) A.4. Fireman's Hood, with Bib, Majestic PAC II Style (FRMN/550/P84 PAC II) A.5. Fireman's Boots, non-insulated, felt-lined, LaCrosse FireTech SSF500 (FRMN/200/SSF 500) A.6. Fireman's Belt, body guide, `D'-ring (FRMN/150) A.7. Hatchet, 1.5lb pickhead, with sheath, Trooper (FRMN/151) A.8. Fireman's Axe, 6lb pickhead, wooden handle with bracket, Trooper (FRMN/255) A.9. Fireman's Lifeline, 30m (98.5ft), braided (FRMN/700/11980) A.10. Fireman's Flashlight, explosion-proof, waterproof, with spare batteries, Koehler Worksafe I Model 2224 (FRMN/650-2224FL) A.11. Fireman's Oxygen (02) Depletion Meter, basic multi-gas, intrinsically safe, with alkaline battery, Aim Pilot Model 650 (FRMN/650) A.12. Fireman's Suit Carrying Case, soft nylon, zippered with front pouch (FRMN/600) B.1. Self Contained Breathing Apparatus (SCBA), low pressure, 2216 psi, with aluminum/composite cylinders, wrapped in fiberglass, kevlar-glass or carbon-fiber, positive pressure, first stage regulator flows over 1350 l/min, hard carrying case, Interspiro Spiromatic S4 Model 4515 (FRMN/9001/S3/S4/CUST/TYP) B.2. Spare Cylinder, low pressure, 2216 psi, aluminum, wrapped or carbon-fiber cylinder.
     
    Ratings 1. Lifeline - 800 lbf (363 kgf) Proof Load / 4400 lbf (1996 kgf) Breaking Load 2. Oxygen (O2) Depletion Meter - intrinsically safe, Class 1, Groups A. B, C and D 3. Self Contained Breathing Apparatus (SCBA) - Capacity of free air 45 cu.ft (1274 litres), charging pressure 2216 psi, duration 30 minutes
     
    Service Restrictions 1. Unit Certification is not required for these products. 2. Lifeline is to be fireproof, and is not to be coated with material not tested to be fireproof. The lifeline is also to be at least 30m (98.5ft) in length. 3. Suspenders are to be worn inside of and protected by the Coat.
     
    Comments 1. Components not tested, or demonstrated to be tested, against any standard include - Helmet, Suspenders, Gloves, Boots, Belt, Pick Axe & Sheath, Pickhead Fire Axe & Bracket, Flashlight. 2. Fireman's Outfit and SCBA together comply with USCG NVIC 4-68 "Protective Equipment Required For Fireman's Outfits". 3. Reconditioned SCBA units, including Interspiro as listed above, are not covered by this PDA Certificate without separate certification of the reconditioning process. 4. This Fireman's Outfit and SCBA may also be used, where indicated, on vessels and facilities flying the flags of states other than the United States of America.
     
    Notes and Documentation 1. UL Certificate of Compliance MH14918-220800 / October 4, 2000 for NFPA 1971-2000 "Standard on Protective Ensemble for Structural Fire Fighting" (Pant, Coat, Fireman's Hood); 2. Washington Chain and Supply Inc. Certificate of Compliance R-1095 / November 23, 2004 (Lifeline); 3. CSA International Certificate of Compliance 1009410 (LR 105607-3) / September 28, 2000 (Oxygen Depletion Meter); 4. National Institute for Occupational Safety and Health Listing for Spiromatic, Spiromatic S2 and Spiromatic S3 9030, 6630, 4530 and 4515 Open-circuit, pressure demand, entry and escape SCBA or Combination SCBA and Supplied Air Respirator; NIOSH approval number TC-13F-132 (SCBA); 5. Department of Health and Human Services Letter of approval for the Spiromatic S4, Spirotek T4 and various regulator assemblies and parts; letter dated October 23, 2003 from DHHS on behalf of NIOSH and MSHA (SCBA); 6. Safety Equipment Institute Certification Letter of Compliance with NFPA 1981, Standard on Open-Circuit Self-Contained Breathing Apparatus for Fire and Emergency Services, 2002 Edition; certification letter # SBA INS 04 dated October 29, 2003 (SCBA).
     
    Term of Validity This product/model is covered under Product Design Assessment (PDA) Certificate # 05-HS473282-PDA, dated 10/Jan/2005. This PDA Certificate expires Jan of 2010. It will remain valid for the 5 years from date of issue or until the Rules or specifications used in the assessment are revised (whichever occurs first).
     
    ABS Rules 2005 Steel Vessel Rules 1-1-4/3.7, 4-7-3/15.5.1
     
    National Standards 46CFR Ch.1/96.35 Fireman's Outfit
     
    International Standards SOLAS 1974 as amended, Reg.17 Fireman's Outfit
     
    Model Certificate Model Certificate No Issue Date Expiry Date
    PDA 05-HS473282-PDA 10/JAN/2005 09/JAN/2010


      
                     ABS       
                                                                                                                                                                                                                         (Pending)

Prices subject to change without notice. Sales and specials are on a first-come, first-serve basis, and no orders will be held without a confirmation deposit being received. All items are subject
to availability. Although WFS Co. does keep a well-stocked inventory of products advertised on this website, we cannot guarantee that the particular product you see on this website will be
available on the showroom floor. Please call ahead to verify. Discounts and special offers may be offered to qualified end users. Please ask for more details and information on how you may qualify.

Send mail to tanya@westernfireandsafety.com with questions or comments about this web site.
Copyright © 2006 Western Fire & Safety Co., Inc.
Last modified: 07/22/2007 - by Tanya H Agha
Hit Counter